Weak Base Anion Resin D301
High-capacity acid absorption with gentle regeneration.
Overview
Where this grade earns its place.
A tertiary amine, macroporous weak base anion resin with a capacity roughly double that of strong base resin in the same volume. It absorbs free mineral acids at near-stoichiometric caustic dose, which makes it the economical first anion stage ahead of a strong base polisher — and a strong performer in decolorization duty.
Typical applications
- First anion stage in two-stage demineralization
- Acid removal from pickling and plating rinse water
- Decolorization of sugar, starch and fermentation broths
- Removal of strong mineral acids from organic solvents
- Recovery of acids from spent process liquors
Packaging
- 20 kg PE-lined woven bag (standard)
- 40 bags per pallet, shrink-wrapped — 800 kg net
- 1 000 bags per 20′ FCL — 20 t net
- Private-label bag printing from one pallet
Documentation
- Certificate of analysis per production lot
- Safety data sheet (GHS)
- Design guide: WBA + SBA staged demineralization
- Hazard classification report (not regulated for sea transport)
Batch certificate of analysis is issued for every production lot and sent before shipment on request.
Technical data
Specification — Weak Base Anion D301
Typical values for the grade as shipped. Tolerances are confirmed on the batch certificate. Tell us if you need a tighter bead-size cut or a different ionic form.
| Polymer matrix | Styrene–divinylbenzene copolymer, macroporous |
|---|---|
| Functional group | Tertiary amine, weakly basic |
| Ionic form as shipped | Free base |
| Total exchange capacity | ≥ 1.40 mmol/mL; ≥ 4.80 mmol/g dry |
| Moisture content | 50–60 % |
| Bulk density | 640–720 g/L |
| Effective bead size | 0.40–0.70 mm |
| Uniformity coefficient | ≤ 1.60 |
| Max. operating temperature | 100 °C |
| pH range | 0–9 |
| Swelling, free base → salt | ≤ 5 % |
| Regeneration | 2–4 % NaOH; Na₂CO₃ or NH₃ also workable |
Values are typical for standard production and are not a substitute for the batch certificate of analysis. For potable-water, food-contact or nuclear applications, request the compliance file before ordering.
Related grades